The 3500/20 Rack Interface Module (RIM) is an essential component of the Bently Nevada 3500 Machinery Monitoring System, providing the primary interface to the 3500 rack. It serves a critical role in system configuration, machinery data retrieval, and communication management. Below are the key details:
Description & Functionality:
- Primary Role:
- The RIM enables configuration of the rack and retrieval of machinery data through a proprietary communication protocol.
- It provides a communication link between the Bently Nevada 3500 rack and external communication processors, such as TDXnet, TDIX, and DDIX.
- Rack Position:
- The RIM must be installed in Slot 1 of the 3500 rack, which is adjacent to the power supplies.
- Functions:
- Rack Management: It supports the configuration of the rack and the retrieval of real-time machinery data from all installed monitoring modules.
- External Communication: Facilitates communication with external processors for data transfer or remote monitoring.
- Critical Monitoring:
- The RIM is not part of the critical monitoring path of the 3500 system. Its failure will not affect the continuous monitoring and operation of the machinery system itself.
- Redundancy (TMR):
- For Triple Modular Redundant (TMR) applications, a TMR version of the RIM is required.
- In addition to standard RIM functions, the TMR RIM performs monitor channel comparison. This involves the monitor voting mechanism:
- The TMR RIM compares the outputs of three redundant monitors.
- If the output of one monitor diverges from the others by more than a configured threshold, the RIM flags the faulty monitor and generates an event in the System Event List, indicating an error.
Key Features:
- Primary Interface to the 3500 rack.
- Slot 1 location requirement (next to power supplies).
- Supports external communication processors like TDXnet, TDIX, and DDIX.
- Provides common functions for the entire rack without affecting critical monitoring operations.
- TMR RIM configuration enables monitor voting and detection of discrepancies in redundant monitoring systems.
- A single RIM is required for each 3500 rack.
Ordering Information & Configuration:
The 3500/20 Rack Interface Module typically comes as part of a complete 3500 Machinery Monitoring System. If you’re ordering or configuring a system with TMR, be sure to specify the TMR version of the RIM for redundancy.
WeChat