The 200-530-025-014 CMC 16 Condition Monitoring Card is the core component of the Vibro-Meter VM 600 series CMS. It functions as an intelligent front-end Data Acquisition Unit (DAU) that collaborates with the VM 600 CMS software to gather, analyze, and transmit results to a host computer via the VM 600 series CPU M module with Ethernet controller or directly through serial links.
Key Features
- Fully programmable inputs for various signal types including:
- Speed and phase reference
- Vibration (acceleration, velocity, displacement)
- Dynamic pressure and airgap rotor profiles
- Any dynamic or quasi-static signals
- Signal input via:
- Machinery Protection Cards (MPC 4) via the VM 600 ‘Raw Bus’ and ‘Tacho Bus’
- Screw terminal connectors on the IOC 16T
- On-board signal conditioning, EMC protection, and extensive filtering capabilities (16 programmable anti-aliasing filters)
- Capable of high-resolution data acquisition and processing (waveforms, spectra, orbits)
- Supports adaptive monitoring techniques for dynamic alarm set points
- Provides various metrics (RMS, peak values) and configurable bands based on acquired spectra
- Transient Mode for higher density logging during events
Specifications
Speed/Phase Reference Input
- Triggering Method: Rising or falling edge
- Input Voltage Range: 1 to 24 V pulse (AC coupled in -24 V / +24 V range)
- Frequency Range: 0.25 to 10,000 Hz
- Maximum Pulses per Revolution: 128 (speed calculation), 1 (phase reference)
- Minimum Rise Time: 4 volts/second
- Minimum Pulse Duration: 10 µs
- Common Mode Voltage: Max 50 V
- Machine Speed Resolution: ±1 rev/min
- Maximum Inputs Allowed: 4 among the first four channels
Vibration and Analog Inputs
- A/D Converter: 1 converter per channel, 14 bits (transmitted values truncated to 12 bits)
- Max Sampling Rate: 100 kHz
- Accuracy:
- AC Measurement: 1% of input FSD
- DC Measurement: 1% of input FSD
- Input Range (Switch Selected):
- AC: 0.1, 0.2, 0.5, 1.0, 2.0, 4.0, 10.0, 20.0 V FSD
- DC: ±24 V FSD, Thermocouple: 61.022 mV FSD
- Max Frequency Span: 20 kHz
- Signal/Noise Ratio: > 70 dB up to 10 kHz, > 60 dB at 20 kHz
- Crosstalk Isolation: < -75 dB
- Common Mode Voltage for Inputs: 50 V (vibration/process), 3 V (thermocouple)
Logging Acquisition
Background Logging
- Order Tracking Range (Synchronous): 15 RPM to 30,000 RPM
- Order Tracking Span: 1.56 to 400 orders
- Fixed Frequency Span (Asynchronous): 0 to 20 kHz
- FFT Resolution: 400 lines
- Real-Time Sampling Rate: 2.56 x frequency/order span
Scheduled Logging
- Order Tracking Span (Synchronous): 0 to 400 orders
- Fixed Frequency Span (Asynchronous): 0 to 20 kHz
- Scheduled Minimum Interval: 1 minute
- Scheduled Maximum Interval: 59 hours
Transient Acquisition
- Maximum Transient Duration: 18 hours 12 minutes
- Storage Interval (Minimum): 200 msecs
Oscilloscope Acquisition
- Scheduled Sampling Rate: 2.56 x frequency span
- Sampling Duration: Various from 0.84 to 668.73 seconds
On-Board Buffer Storage
- RAM Memory: 1 MByte
- Buffer Size for Historic Trends: 26,200 values per CMC 16
Processors
- Microcontroller: Zilog Z8S180
- DSP: Motorola 56002
Communications
- Type: VMEbus to CPU M, RS-485 multi-drop line
- Max Distance to PC: 1220 m (4000 ft) without repeaters
- Transmit/Receive Rate: 19200, 38400 Baud (asynchronous)
Power Supply
- Supply Voltage: 5 VDC ± 5%
- Consumption: 15 W
Environmental Conditions
- Operating Temperature: -25°C to +65°C (-13°F to +149°F)
- Humidity: 0 to 90% non-condensing
- Survival Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity Survival: 0 to 95% non-condensing
Physical Dimensions
- Height: 6 U (262 mm, 10.31 inches)
- Width: 20 mm (0.8 inches)
- Depth: 187 mm (7.4 inches)
- Weight: 0.35 kg (0.77 lb)
Ordering Information
To order, please specify:
- Type Designation: CMC 16 Condition Monitoring Card
- Ordering Number: 200-530-SSS-HHh
- SSS: Firmware (embedded software) version
- HHh: Hardware version (incrementing “H” for major modifications, “h” for minor)
Contact Us
- Phone: +86-15915488782
- Email: uma@meloauto.com
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China
WeChat
Scan the QR Code with wechat