  • Product Details

General Overview

  • Model Number: CC-TDOD51 (Non-Redundant, 9″)
  • Alternate Model Number: CC-TDOD61 (Redundant, 12″)
  • Product Name: Digital Output Bussed 24VDC (DO24V) Module
  • Manufacturer: Honeywell

Functionality

The CC-TDOD51 Digital Output Bussed 24VDC (DO24V) module is designed to control process equipment, such as solenoid valves and interposing relays, by switching reliable 24V digital output signals.


Notable Features

  • Comprehensive Internal Diagnostics: Ensures data integrity.
  • Optional Redundancy: Supports non-redundant (CC-TDOD51) and redundant (CC-TDOD61) configurations.
  • Electronic Overcurrent Protection: Prevents damage from current surges.
  • Configurable Safe-State (FAILOPT): On failure, the output can be set to either hold the last value or switch to a safe value, configurable per channel.
  • Output Types: Supports latched, pulsed, or pulse-width modulated output on each channel.

Bussed 24VDC Output Details

The Digital Output Bussed 24VDC module supports both internal and external field power excitation:

  • Shared Common Ground: All outputs share a common return.
  • Power Source Options: Outputs can be powered either by the system power supply or an external 24V power supply.
  • Galvanic Isolation: External power source can provide isolation from the Series C power system.
  • IOTA Wiring Option: Determines if outputs reference the Series C system power or an external field power source.

FAILOPT (Safe-State) Configuration

  • Per Channel Basis: FAILOPT can be set individually for each channel.
  • Options:
    • Hold Last Value: Retains the last output value on failure.
    • Shed to Safe Value: Switches to a predefined safe value (user-configurable).

Detailed Specifications – SINK TYPE 24V DC

Parameter Specification
Model CC-PDOD51 – 24V Digital Output, Field Isolated, Bussed Output, Coated
IOTA Model CC-TDOD51 (Non-Redundant), CC-TDOD61 (Redundant)
Output Channels 32
Output Type SINK (Open Drain)
Load Voltage 15–30 VDC (Maximum)
Load Current 0.1 A per channel (Maximum)
Galvanic Isolation 1000 VAC RMS (System to Field isolation with user-supplied field power)
On-State Voltage 0 VDC (Load current @ 0.1A max)
Off-State Voltage Typically 24 V
Off-State Leakage Current 100 µA (Maximum)
Turn-On/Turn-Off Time 10 ms (Maximum)
Switchover Gap (Redundancy) None (0 ms)

 


Contact Us

Let us help you find the automation parts you need with reliable quality and dedicated support!

Prev:

Next:

Leave a Reply

Phone +8615915488782

Skype live:.cid.2196513eef2d5350

WhatsApp 8615915488782

WeChat QR Code WeChat

E-Mail uma@meloauto.com

Back to top Back to top

WeChat

WeChat QR Code

Scan the QR Code with WeChat

Leave a message