The Honeywell 8C-IP0102 is a Profibus Gateway Module designed for Series 8 systems, providing robust connectivity and control for industrial applications that require Profibus communication. It supports various advanced features like redundancy, qualification, peer-to-peer communication, and more.
Key Functions:
- Redundancy Support: The PGM module offers redundancy through an interconnected configuration of two IOTAs and two PGMs with a synchronization cable.
- Cold Start Command: It supports cold start functionality for reinitializing the system after power loss.
- Integration with Experion LX: It facilitates integration with Experion LX systems, including alarms, events, and bulk build utilities.
- Qualification & Version Control: Ensures proper versioning and system qualification.
- Peer-to-Peer Communication: Supports communication between Profibus devices in a peer-to-peer mode.
IOTA Characteristics:
- Standard Six-Inch IOTA: Mounts on a standard Series 8 carrier channel assembly, using power supplied through cables.
- Redundancy Configuration: Achieved by connecting two IOTAs with a sync cable (orange CAT5e) for redundancy.
- PROFIBUS Connections: Provides two 9-pin D-sub connectors for PROFIBUS network connections, supporting both standard and extended status bytes.
- FTE Connections: Includes Cat5e connections for standard FTE cables.
- Device Addressing: Three rotary switches allow for easy setting of the FTE device index (address).
Module Connections:
- IOTA Connectors:
- FTE A (yellow) and FTE B (green) connectors for Cat5e cables.
- DB9F connectors for DP network 1 (top) and DP network 2 (bottom).
- Cat5e connector for redundancy sync cable.
- Thumb wheel switches for configuring the PGM FTE index address (odd for primary, even for backup in redundant configurations).
- Mounting: The module mounts on a standard Series 8 IOTA, which in turn mounts into a Series 8 cabinet.
- Power & Grounding: Uses the standard Series 8 power system via I/O Link cables and header board arrangements.
Detailed Specifications:
Module Specifications:
- Model Numbers:
- 8C-IP0102 (Coated)
- 8U-IP0102 (Uncoated)
- Supervisory Network Type:
- Standard FTE node.
- Voltage Rating:
- 24 VDC.
- Current Rating:
- 430 mA.
Temperature:
- Operating Temperature: 0 to 60 °C.
- Storage Temperature: -40 to 85 °C.
PROFIBUS Communication:
- PROFIBUS DP (V0): Supported (includes standard and extended status bytes).
- PROFIBUS DP (V1): Supported, acting as a DP Master Class-2 device for FDM, utilizing vendor-provided DTMs for DPV1 messaging.
- PROFIBUS DP (V2): Not supported in release R110.
- Redundancy:
- DP network media redundancy: Supported using 3rd-party Redundancy Link Modules (e.g., ABB RLM, Siemens Y Link).
- Slave device redundancy: No V1 capability for slave redundancy, but FDM may manage it via DTMs.
- Profibus PA Devices: Supported using 3rd-party PA to DP converters.
Other Features:
- Asset Management: Supported through Honeywell FDM using DTMs for DP slave communication.
- Simulation: Not supported in R110.
- HART over PROFIBUS: Supported using FDM and HART-compliant DP slaves.
PGM Capacities and Limits:
Capacity Item | Limit or Constraint |
---|---|
Maximum number of Series 8 PGMs per Server | 80 (redundant or non-redundant) |
Maximum number of Series 8 PGMs per C300 | 4 PGMs or redundant pairs (8 DP networks). Note: Each PGM can only be assigned to one C300 or redundant pair. |
Maximum number of DP networks per PGM | 2 |
Address range per DP network | 0-125 |
Maximum number of Slaves and Masters per DP network | 125 (Theoretical max). Note: Maximum of 32 devices per RS485 segment; repeaters required to achieve 125. Other factors like memory/latency may limit the actual maximum. |
Maximum number of DSB blocks per PGM | 250 (A DSB is used to represent one slave on the DP network.) |
Maximum number of different DSB (Slave) types per PGM | 20 |
Maximum number of different PDC types per DSB | 16 |
PGM Configuration Specifications:
- PROFIBUS Communication Profiles Supported:
- DP (only) – PGM2 acts as a DP Master Class-1 device.
- PROFIBUS Baud Rates Supported:
- 12 Mbps, 6 Mbps, 3 Mbps, 1.5 Mbps, 500 Kbps, 187.5 Kbps, 93.75 Kbps, 19.2 Kbps, 9.6 Kbps.
- Support for Multi-Master Configurations:
- Yes, multiple masters can be configured.
- Support for PROFIBUS Slave Diagnostics:
- Yes, the system supports slave diagnostics.
- Valid PROFIBUS Station Address Range:
- 0 – 127 (Some addresses are reserved for specific purposes).
- Number of PROFIBUS Networks per PGM2:
- 2 networks.
- Maximum Input Data Size per PGM2 PROFIBUS Network (for DP V0 input data):
- 3.5K Bytes per DP network.
Reserved PROFIBUS Station Addresses:
- Address 0: Master class 2 default address.
- Address 1: Reserved for Master class 1 (PGM2).
- Address 2: Reserved for slave with changeable address.
- Address 126: Reserved for slave with changeable address.
- Address 127: Reserved for broadcast messages.
- Addresses 3 – 125: Reserved for PROFIBUS slaves
About Us
Meloauto – Your Trusted Supplier for Original, Brand-New PLC and DCS Parts Meloauto offer a vast selection of products from globally recognized brands, including Allen Bradley, Bently Nevada, Honeywell, ABB, GE Fanuc, Siemens, Invensys Triconex, ICS Triplex, Foxboro, Yokogawa, Schneider, and Hima, among others. With tens of thousands of new parts ready to ship, Meloauto has successfully served customers across over 50 countries worldwide. We focus on supplying discontinued and hard-to-find items, ensuring each product is in brand-new, original condition.Contact Us
- Phone: +86-15915488782
- Email: [email protected]
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China
WeChat
Scan the QR Code with wechat