The ABB AWT210 combines advanced digital communications with a flexible design for quick setup and operation.
Key features
- Easy Setup: Sensor configuration menus offer step-by-step guidance for hassle-free installation.
- Self-Diagnostics: Advanced diagnostics conform to NAMUR NE 107 for clear device status indication.
- Security Access: Multi-level security prevents unauthorized changes to configuration and calibration.
- One-Button Calibration: Simplifies routine maintenance, saving time and costs.
- Universal Design: Compatible with pH, ORP, conductivity, or EZLink (pH/ORP only) measurements.
- Plug-and-Play Modules: Reduces inventory and enhances operational uptime with options for PROFIBUS™ PA, FOUNDATION™ Fieldbus™, or HART™ communications.
Specifications
Operation
- Display/LCD (W × H): 75 × 65 mm (3.0 × 2.55 in)
Language Support
- English, German, French, Spanish, Italian, Portuguese, Russian, Turkish, Chinese, Polish
Mechanical Data
Terminal Connections
- AWG: 26 to 14 (0.14 to 2.5 mm²)
Input Specifications
pH/ORP/pION Sensor Types
- pH: Glass, Antimony (Sb)
- ORP (Redox): Platinum (Pt), Gold (Au)
- pION: Custom user-programmable
Input Impedance
1 × 10¹³ Ω
Measurement Range and Resolution
Type | Range | Display Resolution | Accuracy | Repeatability |
---|---|---|---|---|
pH | 0 to 14 pH | 0.01 pH | ±0.01 pH | |
ORP | –1500 to 1500 mV | 1 mV | ±1 mV | |
pION | –1500 to 1500 mV | 1 mV | ±1 mV |
Dynamic Response
- <1 second for 90% step change at 0 seconds damping
Damping
- Configurable: 0 to 99.9 seconds
Conductivity Sensor Types
- AWT210:
- 2-electrode
- 4-electrode
- Toroidal conductivity sensors
Conductivity Measurement Range and Resolution
AWT210 2-electrode
Cell Constant | Conductivity Range | Display Resolution | Accuracy |
---|---|---|---|
0.01 | 0 to 200 µS/cm | 0.001 µS/cm | ±1.0% of measurement range per decade |
0.1 | 0 to 2000 µS/cm | 0.01 µS/cm | |
1 | 0 to 20000 µS/cm | 0.1 µS/cm |
AWT210 4-electrode
Sensor Group | Conductivity Range | Display Resolution | Accuracy |
---|---|---|---|
A | 0 to 2000 mS/cm | 0.1 µS/cm | ±0.5% of measurement range per decade |
B | 0 to 2000 mS/cm | 0.01 µS/cm |
AWT210 Toroidal
Sensor Type | Conductivity Range | Display Resolution | Accuracy |
---|---|---|---|
ABB Toroidal | 0 to 2000 mS/cm | 1.0 µS/cm | ±0.5% of measurement range per decade |
EZLink (for Digital pH/ORP Sensors Only)
- Power Consumption (Max): 1.5 mA @ 3.3 V DC (5 mW Max)
- Fixed Length Cable: 1 or 10 m (3.28 or 32.8 ft)
- Digital Sensor Connector IP Rating: IP67 (when connected)
Extension Cable Options
- Lengths: 1, 5, 10, 15, 25, 50 m (3.2, 16.4, 32, 49.2, 82, 164 ft)
- Maximum Length: Up to 60 m (197 ft)
Temperature Input
Temperature Element Types
- Pt100 (2 or 3-wire)
- Pt1000 (2 or 3-wire)
- 3k Balco (2 or 3-wire)
- None (manual temperature compensation)
Measurement Range and Resolution
Temperature Element | Temperature Range | Accuracy | Repeatability |
---|---|---|---|
Pt100 | –20 to 200 °C (–4 to 392 °F) | ±0.1 °C (±0.18 °F) after calibration | |
Pt1000 | 20 to 300 °C (–4 to 572 °F) | N/A | |
3k Balco | User-programmable | N/A | |
None | Manual temperature compensation | N/A |
Temperature Compensation Modes
pH/ORP/pION
Type | Manual | Automatic | Nernstian | Nernstian with Solution Coefficient |
---|---|---|---|---|
pH | Yes | Yes | Yes | Yes |
ORP | Yes | Yes | ||
pION | Yes | Yes |
Conductivity
Temperature Element | Conductivity Types |
---|---|
AWT210 2-electrode | 0 to 15% NaOH, 0 to 20% NaCl, 0 to 18% HCl, 0 to 20% H2SO4, Pure water neutral salt, Pure water trace base, Pure water trace acid, User-defined |
AWT210 4-electrode | Same as AWT210 2-electrode |
AWT210 Toroidal | Same as AWT210 2-electrode |
Power Supply
FF and PA Models
- Supply Voltage: 9 to 32 V DC (General), 9 to 24 V DC (Intrinsically Safe)
- Quiescent Current: 15 mA
HART Models
- Supply Voltage: 14 to 42 V DC (General), 14 to 30 V DC (Intrinsically Safe)
- Polarity Safe: Yes
- Lift-off Voltage: 14 V DC
- Under-voltage Protection: Supply voltage < 12 V DC results in < 3.8 mA
Maximum Load
- Calculated as: Max. load = (supply voltage – 14 V) / 22 mA
Output (HART Models)
- Configured Range: 4 to 20 mA, user-programmable across measurement range (Linear and Non-linear)
Dynamic Range
- 3.8 to 20.5 mA with alarm levels at 3.6 mA (low) and 21 mA (high)
Environmental Data
- Operating Temperature: –20 to 60 °C (–4 to 140 °F)
- Humidity: < 95% RH non-condensing
- Storage Temperature: –40 to 70 °C (–40 to 158 °F)
- Vibration: IEC 60068-2-6 Test FC
Approvals, Certification, and Safety
Factory Mutual (cFMus) Intrinsic Safety
- Available with polycarbonate & aluminum enclosures
- Class I, DIV 1: Groups A, B, C, D; T4
- Class II, DIV 1: Groups E, F, G; T4
- Class I, ZONE 2: AEx/Ex ic IIC T4 Gc
Enclosure Type/Ingression Protection Classification
- Rating: 4X*/IP66
- Ambient Temperature Range: –25 °C ≤ Ta ≤ 60 °C
Additional Safety Certifications
- ATEX, IECEx & UKEX:
- Intrinsic Safety: II 1 G Ex ia IIC T4 Ga
- II 3 G Ex ic IIC T4 Gc
EMC
- Emissions and Immunity: Meets requirements of IEC61326 for an industrial environment
Ordering Information for AWT210 2-Wire Transmitter
Model Code
AWT210/X X XX XX XX Option
- Build Revision: Reserved A
- Enclosure Type:
- Polycarbonate: 1
- Aluminum: 2
- Sensor Input Module:
- No sensor module (base unit only): Y0
- Digital EZLink: D1
- pH/ORP (analog sensors): P1
- Conductivity 2-electrode: C2
- Conductivity 4-electrode: C4
- Conductivity toroidal: C1
- Communications Module:
- No communications module: Y0
- HART: H1
- Profibus PA: P1
- FOUNDATION Fieldbus: F1
- Agency Approvals:
- CE only: Y0
- Intrinsic Safety: cFMus and ATEX/IECEx/UKEX: E5
- Non-incendive: cFMus + Intrinsic Safety: cFMus and ATEX/IECEx/UKEX* : E6
(Available only with aluminum enclosure)
Optional Ordering Codes
Add 1 or more of the following codes after the standard ordering information for additional options:
- Mounting Accessories:
- Pipe-mount kit: A1
- Panel-mount kit: A2
- Weathershield: A3
- Pipe-mount + Weathershield: A4
- Cable Entry Options:
- M20 gland pack (2 × M20 cable glands): U1
- M16 gland pack (2 × M16 cable glands): U2
- NPT gland pack (2 × 1/2 in NPT cable glands): U3
- Documentation Language (supplied as standard in English):
- English: M5
- German: M1
- Italian: M2
- Spanish: M3
- French: M4
- Portuguese: MA
- Chinese: M6
- Polish: M9
- Turkish: MT
Spare Parts
Communications Module Assemblies:
- HART module: 3KXA877210L0051
- PA module: 3KXA877210L0052
- FF module: 3KXA877210L0053
Sensor Module Assemblies:
- pH/ORP module for analog sensors: 3KXA877210L0014
- 2-electrode conductivity module: 3KXA877210L0013
- 4-electrode conductivity module: 3KXA877210L0011
- Toroidal conductivity module: 3KXA877210L0012
- EZLink digital module: 3KXA877210L0015
Gland Packs (packs of 2):
- M16 standard gland: 3KXA877210L0112
- M16 Exe gland: 3KXA877210L0115
- M20 standard gland: 3KXA877210L0111
- M20 Exe gland: 3KXA877210L0114
- 1/2 in NPT standard gland: 3KXA877210L0113
- 1/2 in NPT Exe gland: 3KXA877210L0116
Mounting Kits:
- Panel-mount kit (including fixings, flanges, clamps, and seal): 3KXA877210L0101
- Pipe-mount kit (including pipe-mount adaptor plate, brackets, and fixings, excludes pipe): 3KXA877210L0102
- Wall-mount kit: 3KXA877210L0105
- Weathershield kit (suitable for AWT210/AWT420): 3KXA877210L0103
- Weathershield and pipe-mount kit (suitable for AWT210/AWT420): 3KXA877210L0104
Contact Us
- Phone: +86-15915488782
- Email: [email protected]
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China
WeChat
Scan the QR Code with wechat