The Bently Nevada 170180-01-05 Transducer I/O Module is part of the FieldMonitor™ system, used for asset condition monitoring in industrial applications. This module is specifically designed to interface with a variety of transducers, such as proximity probes and accelerometers, and it can be connected to 2-channel monitoring modules to support real-time data acquisition and diagnostics.
Description
- Purpose: Connects external transducers to a FieldMonitor system, allowing data acquisition from proximity probes and vibration sensors (acceleration and velocity).
- Compatibility:
- Supports proximity probes when connected via external Proximitor® sensors.
- Acceleration and velocity transducers are also supported.
- Occupies one slot in a FieldMonitor terminal base and accepts up to two transducer inputs.
Note: For proximity probes without external Proximitor sensors, refer to ordering sheets 141481-01 and 141482-01.
Specifications
Signal Inputs (Model: 170180-01-XX)
- Channel A:
- Input Options: One Proximitor or Accelerometer (with -24 Vdc supply)
- Channel B:
- Input Options: One Proximitor or Accelerometer (with -24 Vdc supply)
Interface Modules Specifications
- Proximitor Sensor/Accelerometer Interface Module:
- Input Voltage Range: 0 to -Vt
- Output Voltage Range: 0 to -Vt
- Frequency Response: -5% at >25 kHz
- Current Draw: 2.0 mA max (without transducer)
- Current Limit Setpoint: 33.6 mA min, 37.6 mA max at 25°C (77°F)
- 2-Wire Velocity Transducer Interface Module:
- Input Voltage Range: 0 to -Vt
- Output Voltage Range: 0 to -Vt
- Frequency Response: -5% at >25 kHz
- Input Impedance: 9.98 ± 0.02 kΩ
- Current Draw: 2.0 mA max (without transducer)
- Velomitor Piezo-Velocity Transducer:
- Input Voltage Range: 0 to -Vt
- Output Voltage Range: 0 to -Vt
- Nominal Bias Voltage: -12 Vdc
- Regulated Current: 3.00 to 4.10 mA
- Frequency Response: -5% at >25 kHz
- Current Draw: 1.5 mA max (without transducer)
- -18 V Proximitor Interface Module:
- Input Voltage Range: 0 to -Vt
- Output Voltage Range: 0 to -Vt
- Supply Voltage: -17.75 to -18.24 Vdc
- Frequency Response: -5% at >25 kHz
- Current Draw: 2.0 mA max (without transducer)
Ordering Information
Transducer I/O Module Part Number
- Part Number: 170180-XX-XX
- 170180-01-05 denotes the specific configuration for this module.
Ordering Options
- I/O Module Type (A):
- 01: Dual Proximitor/Accelerometer I/O Module
- Hazardous Area Approval (B):
- 05:
- Division 2/Zone 2 for Monitor
- Division 1, Zone 0/1 for Transducers
- Requires use of the 1701/06 Isolator Terminal Base for hazardous area applications.
- 05:
This configuration, 170180-01-05, is suitable for environments where Division 2/Zone 2 ratings are needed for monitors and Division 1/Zone 0/1 ratings for transducers. The module is designed to interface robustly with proximity and vibration monitoring transducers in critical industrial environments.