Description
The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module designed for use in a 3500 Machinery Protection System. It receives input signals from proximity probes or magnetic pickups, converting them into digital Keyphasor signals. These signals indicate when the Keyphasor mark on a rotating shaft coincides with the Keyphasor transducer, providing crucial rotational speed data. The module can handle up to four Keyphasor signals in a standard configuration or up to eight in a paired configuration.
Specifications
Power Consumption:
- 3.2 Watts (typical)
Signal Inputs:
- The module accepts up to two transducer signals per channel, from proximity probes or magnetic pickups.
- Input range for Non-Isolated I/O modules: +0.8 V to -21.0 V
- Input range for Isolated I/O modules: +5V to -11V
- Passive magnetic pickups require a minimum shaft speed of 200 rpm (3.3 Hz).
Input Impedance:
- 21.8 kΩ (minimum)
Signal Conditioning:
- Speed/Frequency Signal Ranges: 1 to 1,200,000 cpm (0.017 to 20 kHz), supporting multiple events per revolution up to 20 kHz.
- Output range: 1 to 99,999 cpm (0.017 to 1667 Hz)
- Accuracy (at +25°C / +77°F):
- Non-processed signals:
- 0.017 to 100 Hz: ±1 cpm
- 101 to 500 Hz: ±8 cpm
- 501 to 20 kHz: ±1% of cpm
- Processed signals:
- 0.017 to 60 Hz: ±1 cpm
- 61 to 150 Hz: ±8 cpm
- 151 to 20 kHz: ±1% of cpm
- Non-processed signals:
Transducer Conditioning:
- Auto Threshold: Minimum 2 V peak-to-peak amplitude for triggering, with a minimum frequency of 120 rpm (2 Hz).
- Manual Threshold: User-selectable from 0 to -20 V DC, with a minimum signal amplitude of 500 mV peak-to-peak.
- Hysteresis: Adjustable from 0.2 to 2.5 Volts.
Outputs:
- Two buffered Keyphasor outputs at the front via coaxial connectors, and two more outputs at the back via Euro-style connectors.
- Output Impedance: 504 Ω maximum for buffered output.
Keyphasor Transducer Power Supply:
- -24 V DC, 40 mA maximum per channel.
Ordering Information
Model Number: 3500/25-02-01-01 (or variations depending on specifications)
Key Features to Specify:
- A – Number of Channels:
- 0 2: Two half-height 2-channel Keyphasor cards (order for 4 channels).
- B – Type of I/O Module:
- 0 1: I/O module with Internal Terminations.
- C – Agency Approval Option:
- 0 0: Not required.
Spares
- 149369-01: Enhanced Keyphasor Module (can replace 125792-01 Keyphasor Module).
- 125800-01: Keyphasor I/O Module with Internal Terminations.
Ordering Considerations
- External termination blocks cannot be used with internal termination I/O modules.
- When using external terminations, the external blocks and cables must be ordered separately.
- For more advanced signal processing functions, consulting a Bently Nevada sales representative is recommended.
Contact Us
- Phone: +86-15915488782
- Email: uma@meloauto.com
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China
WeChat