Overview:
The FTA-T-02 module is part of the Fail-Safe Controller System Family (FSC) Version 80x.x, an integrated safety solutions platform designed to secure operations, plant equipment, and personnel while ensuring high availability of plant operations. This module is a crucial part of high-integrity process control and safety functions in critical applications, providing fail-safe digital outputs for emergency shutdown and safeguarding functions.
Key Features:
- Quadruple Modular Redundant (QMR) Technology: Ensures high availability and fault tolerance, making it suitable for safety-critical applications.
- Wide Range of Applications: Used in systems such as burner/boiler management, process safeguarding, turbine and compressor safeguarding, fire and gas detection, and pipeline monitoring.
- Safety and Process Control Integration: Integrates seamlessly with both TPS System’s Universal Control Network (UCN) and Experion System, ensuring the safe operation of high-integrity systems while isolating emergency shutdown (ESD) functions on a separate safety network.
Specifications:
- Output Channels:
- 24 channels of fail-safe digital output, supporting 24 VDC, 48 VDC, or 60 VDC output voltage ranges.
- Output Characteristics:
- Fail-Safe Output: Ensures the output is driven to a safe state in case of failure.
- Open-Collector (Current Sinking) NPN Transistors: Suitable for controlling external devices in fail-safe applications.
- Voltage Range:
- Configurable for 24 VDC, 48 VDC, or 60 VDC depending on the application.
- Isolation:
- Galvanic Isolation (photo coupler) to protect against voltage surges and electrical interference.
- Typically rated for 500 V or higher between output channels and the field device.
- Surge Withstand Capability:
- Compliant with ANSI/IEEE C37.90.1-1978 for surge protection.
- Failure Detection and Recovery:
- Designed with redundancy schemes such as 1oo1D, 1oo2D, and QMR (Quadruple Modular Redundancy) to ensure continuous safe operation even in case of faults.
- Supports 1oo1, 1oo2, and 2oo4D voting schemes for robust fault tolerance.
- Status Indicators:
- LED indicators for module and channel status, providing easy diagnostics for field personnel.
- Termination:
- Screw terminals or compression connectors for secure and reliable field wiring.
- Approvals:
- Typically CE, UL, FM, and TUV certified for safety applications.
Typical Applications:
- High-integrity process control in safety-critical environments.
- Burner/boiler management systems for safe operation of combustion equipment.
- Process safeguarding for chemical, petrochemical, and other hazardous process industries.
- Turbine and compressor safeguarding for machinery protection.
- Fire and gas detection systems to ensure operational safety.
- Pipeline monitoring to protect assets and personnel in pipeline operations.
Architecture Flexibility:
The FTA-T-02 module supports flexible configurations depending on the criticality of the application:
- 1oo1D: Single-channel with diagnostics for lower-risk applications.
- 1oo2D: Dual-channel for higher availability and fault tolerance.
- QMR: Quadruple Modular Redundancy for the most stringent safety requirements.
Each configuration supports various voting schemes for high-integrity, fault-tolerant process control.
Safety-Related Modules
The certified version of the operating system supports the following tested modules within the
approved configurations in safety-related applications:
- Module Number: FTA-T-02
- Module Description: Fail-Safe Digital Output FTA (24/48/60 VDC, 24 channels)
Contact Us
- Phone: +86-15915488782
- Email: uma@meloauto.com
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China
WeChat
Scan the QR Code with wechat