The MVI69L-MBS is a Modbus Serial module designed for CompactLogix™ controllers, optimized for smaller applications requiring communication between a limited number of Modbus Serial devices. This module simplifies commissioning with its Add-on Profile and Add-on Instruction, ensuring efficient integration. It features a single serial port and supports both Master and Slave modes, offering flexible connectivity to Modbus-compatible devices.
Key Features and Benefits
- Compatibility:
- Works with CompactLogix processors with 1769 I/O bus capability (v16 or later).
- Note: Does not support MicroLogix 1500.
- Simplified Integration:
- Add-on Instruction: Automatically creates UDTs (User-Defined Types) for logical definitions of I/O, status, and control data.
- Add-on Profile: Enhances integration with CompactLogix systems.
- Diagnostics and Configuration:
- Diagnostic data is accessible in controller tags, enabling decisions based on system health.
- Configuration is stored in the CompactLogix project file (ACD), providing backup and easy restoration.
- Performance Benefits:
- Acts as a co-processor, minimizing impact on the PLC scan time.
- Supports up to 240 words of I/O data, ensuring robust data handling.
- Flexibility:
- The application port can operate as either a Modbus Master or Slave.
- As a Master, it supports up to 30 fully configurable Modbus commands.
- Implements floating-point data movement, including support for Enron and Daniel-style formats.
- Applications:
- Ideal for OEMs and Machine Builders requiring efficient Modbus communication for CompactLogix systems.
Technical Specifications
Configuration
- Tool: ProSoft Configuration Builder (software).
- I/O Size: 240 input/output words (16-bit integers).
Communication Parameters
- Baud Rate: 110 to 115K baud.
- Data Settings:
- Stop Bits: 1 or 2
- Data Size: 7 or 8 bits
- Parity: None, Even, Odd
- RTS Timing Delays: 0 to 65535 milliseconds.
Modbus Protocols and Modes
- Supported Modes:
- RTU (binary) with CRC-16.
- ASCII with LRC error checking.
- Function Codes Supported:
- Read/Write: Coils, Input Status, Holding Registers, Input Registers.
- Specialized: Diagnostics, Report Slave ID, Mask Write, and more.
Master and Slave Functionality
- Modbus Master:
- Issues up to 30 configurable commands.
- Features configurable polling (continuous or on-change).
- Provides error codes and slave status lists.
- Modbus Slave:
- Allows remote Masters to interact with module data.
- Configurable node address: 1 to 247.
- Includes error codes, counters, and port status.
Hardware Specifications
- Dimensions: Standard 1769 single-slot module.
- Current Load: 450 mA max @ 5 VDC.
- Operating Temperature: 0° C to 60° C (32° F to 140° F).
- Storage Temperature: -40° C to 85° C (-40° F to 185° F).
- Humidity: 5% to 95% RH (non-condensing).
LED Indicators:
- OK: Module Status.
- ETH: Ethernet Communication.
- P1: Serial Communication.
- BP: Backplane Connectivity.
- CFG: Valid Configuration.
Ports:
- Debug Port: 10/100 Ethernet Port.
- Application Port:
- RS-232, RS-485, or RS-422.
- RJ45 (DB-9F with cable provided).
- Configurable RS-232 handshaking.
- 500V Optical isolation from backplane.
Included Accessories:
- RJ45-to-DB9M cable (application port).
- DB-9F breakout board.
Applications
The MVI69L-MBS is well-suited for applications requiring streamlined communication between CompactLogix controllers and Modbus devices. Its compact design and ease of integration make it a go-to choice for OEMs and machine builders.
Contact Us
- Phone: +86-15915488782
- Email: uma@meloauto.com
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China