The PEPPERL+FUCHS KFD2-VR4-Ex1.26 is an isolated barrier designed for intrinsic safety applications. It facilitates the safe transmission of vibration sensor signals from hazardous areas to a control system in safe areas. This device provides either a voltage or current supply to vibration sensors such as those from Bently Nevada or other accelerometers.
Functionality and Output
- Power Supply for Vibration Sensors: The device delivers a specific current or voltage depending on the type of sensor:
- For 2-wire sensors: It provides supply currents of 3.6 mA, 5.3 mA, or 8.9 mA.
- For 3-wire sensors: It supplies 18 V at 20 mA.
This ensures that both 2-wire and 3-wire vibration sensors receive the necessary power and signal transmission.
Technical Specifications
General Specifications
- Signal Type: Analog input.
- Safety Integrity Level (SIL): SIL 2, meeting functional safety standards.
- Rated Voltage: 19 to 30 V DC.
- Power Consumption: Max 1.6 W.
- Power Dissipation: Max 1.2 W.
Input and Output
- Input Connections:
- Common terminal (4) and individual terminals for signal and supply (terminals 1, 2, 3, 5, and 6).
- Input resistance: 10 kΩ (terminals 4, 6-/2-).
- Output current:
- > 10 mA at -21 V or > 20 mA at -18 V (terminals 4 and 5).
- 5.3 mA ±0.4 mA at -10 V (terminal 4 and 1).
- 3.6 mA ±0.7 mA at -10 V, 20°C (terminal 4 and 3).
- Transmission Range: -20 … 0 V.
- Output Connections:
- Control side connections: Terminals 7- (signal negative), 8+ (signal positive).
- Output Resistance: 24 Ω typical, 27 Ω maximum.
- Load: Minimum 9 kΩ for 3-wire sensors, 2 kΩ for 2-wire sensors.
Transfer Characteristics
- Cut-off Frequency:
- 10 kHz (-0.1 dB)
- 20 kHz (-1 dB)
- DC Transfer Error: Less than 10 mV (with a 10 kΩ load).
- AC Error: ±5 mV at 20°C (68°F) for alternating components (square or sine waves), within specified input ranges.
- Temperature Influence: Less than 100 ppm of span per K.
- Time Delay: 7.1 ±0.3 µs.
Ripple
- 200 kHz bandwidth: < 20 mVrms.
- 20 kHz bandwidth: < 3 mVrms.
Galvanic Isolation
- Output/Power Supply Isolation: Functional insulation with a rated insulation voltage of 50 V AC.
- Safe Galvanic Isolation: Voltage peak value of 375 V according to IEC 60079-11.
Certifications and Compliance
- EU-type Examination Certificate: BAS 02 ATEX 7206.
- Marking:
- Ex ia Ga IIC (gas)
- Ex ia Da IIIC (dust)
- Maximum Safe Voltage: 253 V.
- IECEx Approval: IECEx BAS 05.0078, IECEx BAS 10.0085X.
- EMC Compliance: EN 61326-1:2013, EN 61326-3-2:2018.
- Environmental Compliance:
- EMC: NE 21:2017, EN IEC 61326-3-2:2018.
- Protection against electrical shock: UL 61010-1.
- Degree of Protection: IP20, suitable for industrial locations.
- Ambient Temperature: -20°C to 60°C (-4°F to 140°F).
Mechanical Specifications
- Dimensions:
- Width: 20 mm (0.8 inches)
- Height: 119 mm (4.7 inches)
- Depth: 115 mm (4.5 inches)
- Mass: Approximately 125 g.
- Mounting: Can be mounted on a 35 mm DIN rail (EN 60715).
Contact Us
- Phone: +86-15915488782
- Email: uma@meloauto.com
- WhatsApp: +8615915488782
- Business Hours: 24/7 service
- Address: Unit 601, Powerlong International Center, No. 1599 Luling Road, Siming District, Xiamen City, Fujian, China
WeChat
Scan the QR Code with wechat